Dec 14, 2011 what mental images do you have about testing cables with high voltages. The ground runs through the ct and the breaker is tripping on reset. Standard for acceptance testing specifications for electrical. Since the dc is free of capacitive division, it is more effective in. Hipot test is the most common type of electrical safety test. The probes with builtin start switch protect the testing personnel, who. However, the standards state that production hi pot testing should not exceed 1,500vac, or its dcrectified equivalent of 2,121vdc, from input to output or input to ground. What mental images do you have about testing cables with high voltages. During cable pulling, cable is sometimes subjected to physical stress due to excessive force exerted on it that could eventually leads to damaging the outer layer parts that serve as primary protection of the cable. Cableeye hvx system for high voltage cable and harness testing.
To learn more, subscribe to the cirris systems channel and visit. Hipot testing is an abbreviation for high potential testing a category of electrical tests used to verify the effectiveness of electrical insulation in transformers, motors, printed circuit boards, electrical sub. It is commonly used in the industry for acceptance testing prior to energizing the cable and for maintenance testing programs. As electrical safety engineers already know, electrical. The test is usually performed at about 75% of the typical breakdown voltage and is done as a safety net. Terminal spacing problems and tolerance errors in cables.
Mv test spec plant cables equipment rated voltage kv ac testing dc testing hipot test partial discharge test. It is done with a state of art continuously variable high voltage testing set hipot capable of producing 0120 kv dc output voltage. The dielectric withstand hipot test in compliance magazine. Unless the type test was marginal, the routine test, in the end, finds gross defects in the manufacturing process. Often, the hipot hi pot tests are carried out manually, for which a suitable link between the operator, hipot tester and dut is required. The dc hipot is a practice to evaluate the insulation system integrity, i was used for many years with a few problems, for a machines with 5 or more years old we use a voltage test of 1500 v for 460 machines and v for 230 machines. One test cycle can include any combination of a fast dc test, full dc test, and ac test. The test setup and procedures are identical for both ac and dc hipot tests. Dielectric withstand or hipot test the dielectric voltagewithstand test, or hipot high potential test, is designed to stress the insulation of your product far beyond what it will encounter during normal use. Dc hipot test at test start, there will be inrush current. Low voltage directive itself doesnt indicate electronic product needs to pass what kind of test, the meaning of. Connect the ground lead of the hipot tester to a suitable building ground or grounding electrode conductor.
Hi pot dielectric breakdown automated verification howto. The hipot tester current trip level should be set high enough to avoid. The test voltages to be used vary depending upon whether the device or circuit is low or high voltage, a primary or control circuit and whether tested at the factory or in the field. The test measures the insulation resistance between the phases andor between phase and ground. Designed to verify that the insulation of a product is adequate enough to withstand high voltage. A simple water metaphor may help clarify this condundrum. The hipot test is another safety subject of which few of us feel comfortable that we are in control. Acceptable procedures for conducting hipot testing, although varying slightly in technique, have been standardized as either a withstand test or a timeleaking current test.
However, we must understand the difference between hipot dielectric testing and standard high voltage test. High voltage xlpe cable systems technical user guide. Image you are bathing in bath tube, suddenly drier in operating dropping into bath tube, the current flows from drier through your body to ground under this situation. Dc hipots can be used for the following testing applications. One safe and effective testing method offered by industrial tests, inc. Designed to verify that the insulation of a product is. The test is sensitive to arcs or corona so it often finds terminal spacing problems, overmold problems, tolerance errors in idc cables, or any problem that might produce arcs. However, the standards state that production hipot testing should not exceed 1,500vac, or its dcrectified equivalent of 2,121vdc, from input to output or input to. Using the right diagnostic tester keeps equipment operational so that users are able to ascertain whether insulation is functioning properly.
Additional columns may be turned on in the net list to show actual dc voltage, dc current. Vlf testing of shielded power cables by paul brooker, consultant to techrentals division of tr corporation. Is the cable really free of serious insulation defects after passing a dc. The test is a means to qualify a devices ability to operate safely during. Hi one misconception is that a hi pot test is not destructive. Hipot, or high potential, is a class of electronic test equipment used to verify electrical insulation. High voltage xlpe cable systems techincal user guide brugg cables page 4 selection process of cable design 1.
Cableeye hvx system for high voltage cable and harness. When a voltage is raised quickly on a highly capacitive net, there is an inrush of current, even though the net is electrically isolated from other nets. The assumption is that if the insulation can withstand the significantly higher voltage for a given time it will be able to. The following sections of the ansineta standard for acceptance testing specifications for. Timer is also fitted to select the time duration of dc test. The specially developed test probes sp 02 and sp 03 of sps electronic provide ergonomically and technically optimised connections. The test may be between mutually insulated sections of a part or energized parts and electrical ground. How to conduct a hipot test on a 11kv cable answer prabhu krishna. Misinterpretation of the relevant standard may result in the product being subjected to a hipot design verification test to the levels described above.
Electrical safety testing reference guide touch area. Dry testing transformer series is produced, it is completely changed by the backward state of old test transformer stupid, big and heavy, it can produce our matching mounted on a highvoltage silicon stack to provide dc highvoltage test power supply, with a control box,automatic protection microammeters, gap and other ancillary equipment. Advanced test equipment rentals carries a wide selection of hipot and cable testers for your electrical analysis needs. Distance 250m 500m m 2000m cable size m 11kv or less 400mm2 250 125 60 30 185 240mm2 300 150 75 37. Hipot testing we provide services of dc high voltage proof testing of hv cables and switchgears up to 120 kv. Timely conducted testing procedures can help notice the loss of cable insulation integrity, spot signs of its deterioration caused by aging, and therefore prevent cable failure. This guide provides a general overview of the regulatory framework and approval process and explores the specific manufacturing responsibilities and test procedures associated with electrical safety testing. Hipot testing what is hipot testing dielectric strength test. A dielectric withstand test or high potential or hipot test is an electrical test performed on a component or product to determine the effectiveness of its insulation. Deviations from the baseline information permit evaluation of the insulation.
Dc high potential testing dc hipot testing purpose dc hipot testing is used for proof testing shielded cables 5kv to 46kv in the field. Hipot test is short name of high potential high voltage test and it is also known as dielectric withstand test. Hvx with cb29s, 128 test points, expandable external terminals for single channel safety test. A properly wired and insulated electrical system will have negligible current flow during this test. All tests made following cable installation and during the warranty period must be performed in accordance with the applicable specifications. The service life of a cable is defined as its operating time. Ramp down, dwell time test time, trip current, and trip delay soak time are adjustable. What is the purpose of the hipot test, and what hazard does it address or obviate. Once the insulation is charged full test potential, the leakage current drops off to near zero ma. Hipot test makes surety of no current will flow from one point to another point. Hipot testing what is hipot testing dielectric strength. In fact, these tests can result in damage to the cable insulation. First, each of the standards seems to have its own unique voltage which differs from all the other standards. Testing of high voltage cables manual horizon power.
In order to pass the hi pot test, the production folks must make sure that they made it like the design engineer designed it. Can the pcb withstand the voltage stress applied to it. A hipot testmeasures the ability of a product to withstand a high voltage applied between the circuits of a product and ground. These features are used with a dc hipot or ir test. The limited approach boundary for this hipot procedure at volts is 5 ft. Low voltage directive nowadays and emc directive are common use in european community, various member countries should obey them. The test set was dc and the current was limited to a very small value. Hi afton chemical, before to perform this test made a megger readding and if you have a good reading perform the hipot test. Meanwhile, your heart palpitation unregulated and blood pressure falling down causes tragedy cant be redeemed.
I saw cables tested years ago and am wondering if the same method would be productive with motors. Due to the nature of a dc withstand test, setting high and low leakage limits can prove difficult. As we know,a multimeter or ohm meter reading only can determine if a motor winding is open or shorted but cannot checked winding insulation condition. Confirm that all equipment or cable that is not to be tested is isolated from the circuit under test. Jul 31, 2017 the purpose of the dielectric withstand hipot test is to determine whether the insulation from the primary circuit to grounded or accessible parts has sufficient electric strength to withstand the normal overvoltages which could occur in service. Any leakage current exceeding a preset limit reveals the presence of moisture, flux, or other. One of these tests is the hipot test, which is performed when inspecting electrical products.
However, in many cases these tests are not performed, even the basic ac hipot test, because the power required from the test set to charge the capacitance of a large coil can be very high, making the. These tests include a simple ac withstand test and diagnostic testing like tan deltapower factor measurement and partial discharge analysis. Jan 16, 2014 dc hipots can be used for the following testing applications. High voltage field acceptance test prior to being placed in service.
Guidelines for high potential hipot dc testing of medium. Commissioning tests for hv underground cables up to 33kv swp page 5 of standard work practice sp0407 ver 16 ergon energy corporation limited abn 50 087 646 062 this test is required for xlpe and paper lead cables. Between contacts and shielded, the puncture voltage must not less than 1. The test can be done at various times such as acceptance of new cable installation, maintenance testing to track insulation degradation and as a pre and post test for splicing existing cables to new ones. An indicator panel at the top of cableeyes control screen shows the present hipot settings. Electrical safety testing reference guide importer over high. Test method is operating dut and under the status of all switches, link cables. Withstand test apply high voltage on power and ground. An insulation resistance testmeasures the quality of the electrical insulation used in a product. Hipot test is a contraction for high potential hv testing. Hipots ac, vlf dielectric loss measurements partial discharge testing. Manual vlf instruments require the operator to know the.
A hipot, or high potential tester, is capable of measuring the electrical insulation in finished appliances, cables, and other wired systems. I have done this test with several motors in our mills with baker insulation tester instrument about one year ago. A leakage current testchecks that the current that flows between ac source and ground does not exceed a safe limit. Standard for acceptance testing specifications for. Measuaring motor insulation using hi pot tester electrical. The hipot test the dielectric voltagewithstand test is commonly known as the hipot test.
Engineers use hipottesting instruments on cables, wires, circuit boards, appliances, electric motors, and transformers. Some electrical cables have electrical components such as integrated circuits, diodes, capacitors and resistors. I was wondering if anyone has ever heard of hipotting a cable that is still terminated to the bus. The manufacturers recommended method for cable preparation of 15 kv and 5. Oct 15, 2014 the purpose of the routine test is to determine that the production folks covered all their bases. Measuaring motor insulation using hi pot tester 28012012 by lemau 1 comment when we need to evaluate the motor condition, hi pot tester or high potential tester is the common equipment are used. This discussion will also focus on testing of stator windings and not on testing individual bars or coils.
Ac hipot testing ac high potential tests are conducted at voltages above the normal system voltage for a short time. Insulation resistance testing is a nondestructive test procedure. Section 7 of the ansineta standard for acceptance testing specifications for electrical power equipment and systems may be reproduced and used on a cut and paste basis for the particular type of equipment to be tested. Performed by stressing the insulation of the product far. Cable types, design, and associated insulation faults. Additional columns may be turned on in the net list to show actual dc voltage, dc current, dc isolation, ac voltage, ac current, and ac isolation. When performing an inspection, a quality control firm will conduct a variety of special quality control tests, depending on the type of product. The purpose of the dielectric withstand hipot test is to determine whether the insulation from the primary circuit to grounded or accessible parts has sufficient electric strength to withstand the normal overvoltages which could occur in service. This technical article provides general guidelines for high potential hi pot dc testing of mv power cables. The operators manual for the particular test set being used should be read and well understood. The test is a means to qualify a devices ability to operate safely during rated electrical conditions. Insulationresistance test data may be used to establish a trending pattern. Leakage current detected during the high voltage test phase provides a measure of insulation quality. During the test process, keep yourself and all nearby persons at least three feet away.